Vedere la pagina 54
I/O Cells OPAD_DIFFD
Speedster Macro Cell Library
www.achronix.com PAGE 38
Table 1-43: Parameters
Parameter Defined Values Default Value
locationp
locationn
iostandard “LVDS”
drive
rstmode
rstvalue
slew
open_drain “true, “false “false
pvt_comp “none”, “own” “none”
invert_out “off , ”on “off ”
Table 1-44: Output Function Table (rstmode = “async”)
din data_en oe rstn clk pad padn
Table 1-45: Output Function Table (rstmode = “sync”)
din data_en oe rstn clk pad padn
Verilog Instantiation Template
IOPAD_DIFFD #(.locationp(""),
.locationn(""),
.iostandard("LVDS"),
.drive("16"),
.rstmode("async"),
.rstvalue("low"),
.slew("slow"),
.invert_out("off"),
.open_drain("false"),
.pvt_comp("none"))
instance_name (.pad(user_pad), .padn(user_padn)
.din(user_din), .oe(user_oe), .data_en(user_data_en),
.rstn(user_rstn), .clk(user_clk));
“<pad_location>”
“<pad_location>”
See Table12
"2", "4", "6", "8", "12", "16" "16"
“sync, “async “async
“low”, “high “low”
fast”,slow” slow”
XXX0
X
ZZ
X0
X1 Hold previous data Hold previous data
X101 ZZ
0111 01
1111 10
X101 ZZ
XXX0 ZZ
X0
X1 Hold previous data Hold previous data
X101 ZZ
0111 01
1111 10
X101 ZZ
Vedere la pagina 54